TRACE User Guide  TRACE Version 9.8.1
Commands for DG solver

RestartFromFiniteVolume

Use to force restart from finite volume flow solution. Default restart is from DG solution. If a DG solution doesn't exists, the existing finite volume solution will be used.

Usage
all immediate RestartFromFiniteVolume
Domain
all
Since
9.2

ForceWriteCollectiveDGSolution

If active, the solution will be written as a collective solution independent of the restart solution type.

Usage
all immediate forceWriteCollectiveDGSolution
Domain
all
Since
9.2

ForceWriteMultipleDGSolution

If active, the solution will be written as a multiple solution independent of the restart solution type.

Usage
all immediate ForceWriteMultipleDGSolution
Domain
all
Since
9.2

DisableDGSEM

Disables the use of the DG Spectral Element Method (DGSEM), which is the default mode by now.

Usage
DisableDGSEM
Domain
all, blockGroup
Example
all immediate DisableDGSEM
Precondition
Only valid if the solver mode is set to DG.
Since
9.5

UseDGshockCapturing

Enables the use of the DG - FV Hybrid Shock Capturing Method. The algorithm and the lower and upper thresholds may be provided as optional parameters.

Usage
UseDGshockCapturing [options]

Options:

long option short option arguments description
--type -t name name of the shock capturing algorithm (optional)
--lowerThreshold -lt float lower threshold of the shock indicator function between 0 and 1 (optional)
--upperThreshold -lt float upper threshold of the shock indicator function between 0 and 1 (optional)
Domain
all, blockGroup
Example
all immediate UseDGshockCapturing
all immediate UseDGshockCapturing --lowerThreshold 0.001 --upperThreshold 0.5
Precondition
Only valid if the solver is using DGSEM.
Since
9.2

UseDGpositivityPreserving

Enables the use of the DG positivity preserving.

Usage
UseDGpositivityPreserving
Domain
all, blockGroup
Example
all immediate UseDGpositivityPreserving
Precondition
Only valid if the solver is using DGSEM-LGL.
Since
9.2

UseBR1Scheme

Use to apply the BassyRebay1 scheme for the discretization of the viscous terms. Default will be BassyRebay 2 scheme.

Usage
all immediate UseBR1Scheme
Domain
all, blockGroup
Since
9.2

SetDGBasisForm

Sets the basis form type for the DG scheme. Choose between 'MODAL' and 'NODAL' basis functions. For 'NODAL' basis functions, the interpolation node set of the lagrange polynomials has to be specified.

Usage
SetDGBasisForm <basisform> <nodeSetType>
Parameters
basisformchoose between MODAL and NODAL basis functions
nodeSetTypeset node set to Uniform, Legendre-Gauss or Legendre-Gauss-Lobatto
Domain
all, blockGroup
Example
all immediate SetDGBasisForm NODAL Legendre-Gauss-Lobatto
Since
9.0

UseDGUpwindSolidWallFlux

Enables the use of numerical flux function of Roe for the Euler solid wall boundary flux, which is

\begin{equation*} \mathcal{H}^{E} = \mathcal{H}^{Roe}(\boldsymbol{q}^-, \boldsymbol{q}^\Gamma, \boldsymbol{n}), \quad \text{with} \quad \boldsymbol{q}^\Gamma = \boldsymbol{q}^- - \begin{pmatrix} 0 \\ 2 (\boldsymbol{u}^-\cdot \boldsymbol{n}) \boldsymbol{n} \\ 0 \end{pmatrix}. \end{equation*}

By default the boundary flux at Euler solid walls is equal to the pressure contribution of the inviscid flux function in the normal direction, i.e.

\begin{equation*} \mathcal{H}^{E}(p^-, \boldsymbol{n}) = \begin{pmatrix} 0 \\ p^- \boldsymbol{n}\\ 0 \end{pmatrix} \end{equation*}

Usage
UseDGUpwindSolidWallFlux
Domain
all, blockGroup
Since
8.2

SetDGCFLComputationType

Choose a method to compute a CFL number.

Usage
SetDGCFLComputationType <cflComputationMethod>
Parameters
method(one of FaceBased, NodeBased).
Domain
all, blockGroup
Since
9.2