TRACE User Guide
TRACE Version 9.8.1
|
Use to force restart from finite volume flow solution. Default restart is from DG solution. If a DG solution doesn't exists, the existing finite volume solution will be used.
If active, the solution will be written as a collective solution independent of the restart solution type.
If active, the solution will be written as a multiple solution independent of the restart solution type.
Disables the use of the DG Spectral Element Method (DGSEM), which is the default mode by now.
Enables the use of the DG - FV Hybrid Shock Capturing Method. The algorithm and the lower and upper thresholds may be provided as optional parameters.
Options:
| long option | short option | arguments | description |
|---|---|---|---|
--type | -t | name | name of the shock capturing algorithm (optional) |
--lowerThreshold | -lt | float | lower threshold of the shock indicator function between 0 and 1 (optional) |
--upperThreshold | -lt | float | upper threshold of the shock indicator function between 0 and 1 (optional) |
Enables the use of the DG positivity preserving.
Use to apply the BassyRebay1 scheme for the discretization of the viscous terms. Default will be BassyRebay 2 scheme.
Sets the basis form type for the DG scheme. Choose between 'MODAL' and 'NODAL' basis functions. For 'NODAL' basis functions, the interpolation node set of the lagrange polynomials has to be specified.
| basisform | choose between MODAL and NODAL basis functions |
| nodeSetType | set node set to Uniform, Legendre-Gauss or Legendre-Gauss-Lobatto |
Enables the use of numerical flux function of Roe for the Euler solid wall boundary flux, which is
\begin{equation*} \mathcal{H}^{E} = \mathcal{H}^{Roe}(\boldsymbol{q}^-, \boldsymbol{q}^\Gamma, \boldsymbol{n}), \quad \text{with} \quad \boldsymbol{q}^\Gamma = \boldsymbol{q}^- - \begin{pmatrix} 0 \\ 2 (\boldsymbol{u}^-\cdot \boldsymbol{n}) \boldsymbol{n} \\ 0 \end{pmatrix}. \end{equation*}
By default the boundary flux at Euler solid walls is equal to the pressure contribution of the inviscid flux function in the normal direction, i.e.
\begin{equation*} \mathcal{H}^{E}(p^-, \boldsymbol{n}) = \begin{pmatrix} 0 \\ p^- \boldsymbol{n}\\ 0 \end{pmatrix} \end{equation*}
Choose a method to compute a CFL number.
| method | (one of FaceBased, NodeBased). |