TRACE User Guide
TRACE Version 9.8.1
|
The following commands can be used only when TRACE runs in TIME_LINEARIZED mode, i.e. when the GMRES solver is used.
Show information about the ILU preconditioner.
| level | verbosity level of output, possible values: |
| Value | Description |
|---|---|
NONE | no output |
BASIC | basic output |
VERBOSE | complete output |
Use first order Jacobian for GMRES preconditioner.
Set parameters for the numerical differentiation of fluxes in the setup of the system matrix for the linear solver.
| epsilon | (relative) step size for finite differences (default: 1.e-2) |
| threshold | minimal perturbation for finite differences (default: 1.e-2) |
| order | order of the differentiation stencil, has to be integer in the range 1-6 (default: 2) |
Read the steady flow solution which is needed for the setup of the linear solver from another CGNS file than the computation was started with.
| filename | name of the cgns file containing the steady flow solution |
Write 3D field containing the cell-wise \(L^2\)-residual to CGNS output file.