StartPrecond
Activate low Mach preconditioning and define preconditioning parameters. The theory is described here:Low-Mach Preconditioning.
- Usage
StartPrecond [-b/--betaGlobalConst <value>] [-l/--betaGlobalLowerLimitConst <value>] [-k/--KPreconditionConst <value>] [-u/--UnsteadyCharacteristicLength <value>]
- Parameters
-
| betaGlobalConst | Prescribe a constant beta for the current block. |
| betaGlobalLowerLimitConst | Prescribe a lower limit for beta. |
| KPreconditionConst | Case-dependent value. |
| UnsteadyCharacteristicLength | Charateristic length of the test case needed for the computation of unsteady preconditioning parameters. If not given, the steady preconditioning parameters are used. |
- Domain
- all, component, stage, group, blockGroup, block
- Example
all immediate StartPrecond -k 3.0 -l 1E-05
will perform a low-Mach preconditioned calculation with a variable locally determined beta bounded below by 1E-05 and a case dependent value of k equal 3. If you are unsure use k = 3.0 all immediate StartPrecond -k 3.0 -l 1E-02
will perform a low-Mach preconditioned calculation with a variable locally determined beta bounded below by 1E-02, a case dependent value of k equal 3 and stores the calculated beta to the output cgns file. all immediate StartPrecond -b 0.05
will preform a low-Mach preconditioned calculation using a constant beta set to 0.05 all immediate StartPrecond -k 3.0 -l 1E-05 -u 0.4
will perform a low-Mach preconditioned calculation with a variable locally determined beta bounded below by 1E-05, a case dependent value of k equal 3 and a characteristic length for the unsteady preconditioning of u equal 0.4. u should be chosen as a characteristic length of the test case. A common choice is the length of the computational domain.
- Since
- 8.0
StopPreconditionConvergence
Deactivate the convergence acceleration from low Mach preconditioning. The time derivative of the governing equations will not be preconditioned. Therefore, the time step calculation, the boundary conditions and the implicit matrix are not preconditioned. This command works only in combination with the StartPrecond command.
- Usage
all immediate StopPreconditionConvergence
- Domain
- all, component, stage, group, blockGroup, block
- Since
- 9.6
StopPreconditionDissipation
Deactivate accuracy improvement resulting from the low Mach preconditioning. The standard Roe scheme is used instead of the preconditioned Roe scheme. This command works only in combination with the StartPrecond command.
- Usage
all immediate StopPreconditionDissipation
- Domain
- all, component, stage, group, blockGroup, block
- Since
- 9.6
WritePreconditioningParameter
Write the preconditioning parameters and all its limiters in the cgns output for debug purposes. This command works only in combination with the StartPrecond command.
- Usage
all immediate WritePreconditioningParameter
- Domain
- all, component, stage, group, blockGroup, block
- Since
- 9.6