TRACE User Guide  TRACE Version 9.8.1
FSI Simulations

Internal CalculiX Solver

The FSI module allows to carry out coupled fluid-structure simulations in the time domain with CalculiX for aeroelastic and conjugated heat transfer analysis as well as conjugated heat transfer analysis for steady simulations.

To use the FSI solver TRACE has to be compiled with the make flag CALCULIX=yes and the pre-compiled routine CalculiXstep() from CalculiX must be available as a library. Furthermore the ARPACK (libarpack.*) and GFortran (libgfortran.*) libraries also must be installed.

For users with a pre-compiled trace suite: If you have a pre-compiled trace suite then the function CalculiXstep() must be compiled as a shared library with the name: libcalculix.so. Additionally the environment variables LIBRARY_PATH and LD_LIBRARY_PATH must contain the path to the directory of the library file (Example: export LD_LIBRARY_PATH=/path/to/dir/where/libcalculix.so/is/located/:$LD_LIBRARY_PATH; export LIBRARY_PATH=/path/to/dir/where/libcalculix.so/is/located/:$LIBRARY_PATH).

For users compiling the trace suite from source: Either a shared library as explained above or a static library can be used. For a static library the function CalculiXstep() must be compiled appropriately with the name: libcalculix.a. Additionally the environment variable LIBRARY_PATH must contain the path to the directory of the library file. (Example: export LIBRARY_PATH=/path/to/dir/where/libcalculix.a/is/located/:$LIBRARY_PATH).

Build TRACE with the option CALCULIX=yes.

The coupling between flow and structure is introduced with a serial approach. At the beginning of a new timestep the surface pressure at the FSI interface is extrapolated to the next timestep. After the calculation of the structural response the nodal displacements and velocities are passed to the flow solver which then computes the flow field for the next timestep. To increase accuracy this procedure can be repeated for the same timestep with the updated surface pressure being passed to the structural solver. In case of a steady simulation the data is exchanged between the two solvers after a specified amount of TRACE iterations. Currently the FSI module only supports the BDF2 time integration scheme for unsteady simulations.

Furthermore it is possible to let the structural solver perform pre-calculations in order to e.g. extract the structural deformation due to the mean blade pressure. The static deformations are then subtracted from the displacements coming from the structural solver during the coupled simulation. This is necessary if the CFD mesh is based on the already deformed (hot) blade geometry whereas the CSM mesh is based on the undeformed (cold) geometry.

In the follwing tables supported feature combinations are marked with a +.

Aeroelasticity Structured Unstructured
Steady Solver
Unsteady Solver +
Conjugated Heat Transfer Structured Unstructured
Steady Solver + +
Unsteady Solver + +

General CalculiX Setup

There are specific requirements for the CalculiX setup. The first analysis step defined in the CalculiX input file must always contain the loaded surface of the CalculiX model which is part of the fluid-structure interface. This is the surface of the structural model on which the pressure or heat flux from the flow solver is applied to (usually the blade surface). TRACE will use the first step as an initialization step and read the surface mesh of the surface loads defined by a *DLOAD or a *DFLUX card in CalculiX. This surface mesh is then used to compute the interpolation matrices which are needed to map surface data from the structural mesh onto the fluid mesh and vice versa.

Note: Currently no other surface loads (*DLOAD or *DFLUX) defined in the CalculiX input file except for the fluid-structure interface surface are allowed. Body forces defined with the *DLOAD card are not affected by this rule and may be used.

For details on the CalculiX setup the reader is referred to the CalculiX manual (http://www.dhondt.de/).

Setup for Restart

For the steady solver the numerical result from the previous simulation can be used as initialization (e.g. the surface temperature distribution for the CFD setup) for the restart of a steady simulation and thus no special treatment for the steady solver is necessary. However the unsteady FSI solver provides special restart functionality.

To carry out an unsteady restart the TRACE CGNS file together with the file "CCXRestartData.dat" which are both located in the standard 3D output folder (e.g. ../output/cgns/.., specified in the gmc widget "PRE->Solver->Output control->Physical 3D->Standard") must be moved into the input folder of the TRACE simulation. The updated CGNS file is the new main TRACE file und must be prepared with gmc for restart (gmc: PRE->Solver->Global settings->Restart from existing solution). The remaining files of the numerical setup must stay untouched (especially the CalculiX setup). If applicable, the steady/average surface pressure used during the initialization of the original simulation is read from the restart-CGNS file and static and dynamic precalculations are carried out again as in the original simulation since this is necessary to restore the complete hot (geometry) to cold (geometry) transformation data. Subsequently the simulation states of TRACE and CalculiX will be restored with the restart data and the FSI simulation will continue.

Aeroelasticity Setup

CalculiX Setup

If CalculiX is used with modal dynamics the first step in the CalculiX input file (e.g. ccx.inp) could be (following the model definition section of the input file):

*STEP
*MODAL DYNAMIC
1.0E-8, 1.0E-8
*DLOAD
*INCLUDE,INPUT=dloadsurface.dlo
*END STEP

For modal dynamics the eigenmodes must have been calulated with an eigenvalue analysis (*FREQUENCY, STORAGE=YES). For more details on this the reader should consult the CalculiX manual.

Alternatively the first step with full FEM discretization would read:

*STEP
*DYNAMIC
1.0E-8, 1.0E-8
*DLOAD
*INCLUDE,INPUT=dloadsurface.dlo
*END STEP

The (*DYNAMIC) option will trigger implicit time integration in CalculiX with variable time increment.

The file dloadsurface.dlo must contain the surface loads, e.g.:

3327, P2, 0.000000e+00
3981, P3, 0.000000e+00
4672, P2, 0.000000e+00
3234, P4, 0.000000e+00
...

The surface loads for the *DLOAD card should be set to zero otherwise the structure will already deform during the initialization step.

Additionally the surface of the CalculiX model which is part of the fluid-structure interface (defined by a *DLOAD card in the first analysis step) must also be defined as a *SURFACE card with the name "FLUIDINTERFACE" in the model section of the CalculiX input file. E.g.:

*SURFACE, NAME=FLUIDINTERFACE
3327, S2
3981, S3
4672, S2
3234, S4
...

This is required in order to compute the amount of work performed during one timestep at the FSI interface for the structural side.

Performing Pre-calculations

A static pre-calculation is part of the initialisation process of the FSI solver. Thus no seperate preprocessing runs are necessary and it is enough to extend the CalculiX input file appropriately and instruct TRACE at which CalculiX step data is given to or read from CalculiX. The total number of steps in the CalculiX input file must be specified in the TRACE control file together with the steps at which the static pressure from TRACE should be applied to CalculiX and at which the static deformations should be read from CalculiX. It is assumed that the initialization of the flow field in TRACE is the steady (or mean) flow solution.

According to this example the CalculiX input file from above must be extended as follows:

*STEP
*MODAL DYNAMIC
1.0E-8, 1.0E-8
*DLOAD
*INCLUDE,INPUT=dloadsurface.dlo
*END STEP
*STEP, INC=200
*MODAL DYNAMIC,STEADY STATE
1.0E-2, 0.1E-4
*MODAL DAMPING,RAYLEIGH
,,0.,2.e-5
*END STEP
*STEP
*MODAL DYNAMIC
0.0, 0.0
*MODAL DAMPING,RAYLEIGH
,,0.,0.
*include, input=./cload.frc
*END STEP

The corresponding control file commands for TRACE are:

all immediate FSIPreCalculationPerformSteps TURBINE 3
all immediate FSIPreCalculationApplyPressureAtStep TURBINE 2
all immediate FSIPreCalculationReadStaticDeformationAtStep TURBINE 2 ../output/fsi/CalculiXStaticDeformation.dat
all immediate FSIPreCalculationSaveSolverStatusAfterStep TURBINE 2

In this example TRACE will do the following: TRACE will execute CalculiX three times before the coupled simulation starts (all immediate FSIPreCalculationPerformSteps TURBINE 3). The first step is executed during the initialization of CalculiX which is always done by TRACE. During each of the three executions CalculiX will read and perform the next step card (*STEP ... *END STEP). TRACE is instructed to apply the static pressure (from the flow field initialization) to CalculiX just before the second step (all immediate FSIPreCalculationApplyPressureAtStep TURBINE 2) or in other words directly after the initialization step. Subsequently CalculiX will perform a modal dynamic analysis until steady state is reached (*STEP, INC=200; *MODAL DYNAMIC,STEADY STATE...). After CalculiX has finished the second step TRACE will read and store the calculated static deformations from CalculiX (all immediate FSIPreCalculationReadStaticDeformationAtStep TURBINE 2 ../output/fsi/CalculiXStaticDeformation.dat). The static deformations are additionally stored in the file "../output/fsi/CalculiXStaticDeformation.dat" for viewing purposes.

The third and last step which CalculiX reads from the input file will prepare CalculiX for the coupled simulation. Throughout the coupled simulation CalculiX will use the settings of this last step. The last step must always be of a dynamic step type (*MODAL DYNAMIC or *DYNAMIC) for an unsteady simulation. In this example concentrated point loads (*include, input=./cload.frc) are applied which could be used e.g. to model contact forces in joints.

Notice that the surface loads defined in the first step (*DLOAD) are not deleted in subsequent steps and consequently it is enough to specifiy these only in the first step. Only the loading values are manipulated by TRACE.

After all pre-calculation steps the state of the structure is reset to the one which was obtained after the static analysis step (specified by FSIPreCalculationReadStaticDeformationAtStep) or (if no static pre-calculation step was specified) to zero displacements and zero velocities. This behavior can be changed by using the command FSIPreCalculationSaveSolverStatusAfterStep. With this command a CalculiX Step can be selected after which the CalculiX status is saved and used as initialisation for the coupled simulation. In the above example the usage of FSIPreCalculationSaveSolverStatusAfterStep is not necessary and only included for demonstration purposes. Notice that if both commands (FSIPreCalculationReadStaticDeformationAtStep and FSIPreCalculationSaveSolverStatusAfterStep) are used the state from the last CalculiX Step of the two specified takes precedence.

TRACE Setup

There are several control file commands available to setup TRACE for a coupled FSI simulation. The commands are documented in the section FSI.

To give an example of such a setup a blade row with 50 blades is considered. The control file could be as follows:

all immediate FSI TURBINE ccx row02Blade_Wall_ps row02Blade_Wall_ss
all immediate FSIrelaxation TURBINE FixedPoint 1.0
all immediate FSInPseudoTimeStepsCoupling 20
all immediate FSIUnitConversion TURBINE 1.0e-6 1.0e-3 1.0e-3
all immediate FSITransformationMatrix TURBINE transformation.dat
all immediate FSIAnalysisPoint 2 1 1 65 corner_tip_trail_blade_001
all immediate FSISurfaceInterpolationPressure TURBINE NearestNeighbour
all immediate FSISurfaceTecplotOutput TURBINE 16 ../output/fsisurface
all immediate FSIMirrorCoordinate TURBINE y
all immediate FSICyclicSymmetricVirtualPassages TURBINE 10 10
all immediate FSIPreCalculationPerformSteps TURBINE 3
all immediate FSIPreCalculationApplyPressureAtStep TURBINE 2
all immediate FSIPreCalculationReadStaticDeformationAtStep TURBINE 2 ../output/fsi/CalculiXStaticDeformation.dat
all immediate FSIPreCalculationSaveSolverStatusAfterStep TURBINE 2
all immediate FSIExternalSolverActivateNonlinearGeometricEffects TURBINE

The first command (all immediate FSI TURBINE ccx row02Blade_Wall_ps row02Blade_Wall_ss) creates a CalculiX instance with the name "TURBINE". This is the first command which must specified since most of the following FSI commands will relate to a CalculiX instance (in this case the instance "TUBRINE"). Note that currently only a single CalculiX instance is supported. The first argument after the CalculiX instance is the name of the CalculiX input file but without the file extension (ccx.inp -> ccx). Then all TRACE panel families follow which are part of the fluid-structure interface on the fluid side (usually the blade surface).

The second command (all immediate FSIrelaxation TURBINE FixedPoint 1.0) specifies the FSI coupling algorithm. "FixedPoint" means that in each iteration the updated displacement data coming from CalculiX is passed to TRACE with relaxation. If the relaxation factor ist set to 1.0 there is no relaxation. Alternatively the Aitken method can be used: all immediate FSIrelaxation TURBINE Aitken.

The next command (all immediate FSInPseudoTimeStepsCoupling 20) specifies the number of pseudo-time steps TRACE is performing between two consecutive FSI iterations. The first time the structural solver is executed is always the pseudo-time step 0. The number of FSI coupling iterations is then determined by the total number of pseudo-time steps per physical timestep specified in the TRACE setup (via gmc) and the pseudo-time steps set via "FSInPseudoTimeStepsCoupling". If e.g. for the TRACE setup 20 pseudo-time steps per physical timestep are specified TRACE will count the pseudo-time steps from 0 to 19. Setting the number of coupling pseudo-time steps to 10 (all immediate FSInPseudoTimeStepsCoupling 10) will have the consequence that an FSI coupling iteration is performed at pseudo-time steps 0 and 10. Setting it to 5 would result in coupling iterations at the pseudo-time steps 0, 5, 10 and 15. Setting it to 20 or higher results in only one FSI coupling iteration at pseudo-time step 0 (also referred to as loose coupling in literature).

With (all immediate FSIUnitConversion TURBINE 1.0e-6 1.0e-3 1.0e-3) the unit conversion factors are specified. TRACE always uses SI units. In this example CalculiX expects the pressure in MPa (Pa to MPa: 1.0e-6) and returns the displacements (and velocities) in mm (mm/s) (mm to m: 1.0e-3 * mm, mm/s to m/s: 1.0e-3).

To map the structural mesh onto the cfd mesh the transformation matrix is specified via (all immediate FSITransformationMatrix TURBINE transformation.dat). The transformation matrix can be determined with gmc (MTU only), PREP or manually. If no transformation matrix is specified TRACE will try to fit the two meshes onto each other by calculating the area moment of inertia and writes the transformation matrix in the file "transformation.dat".

The motion of a mesh node can be probed with (all immediate FSIAnalysisPoint 2 1 1 65 corner_tip_trail_blade_001). TRACE will then write the displacement of a cfd mesh node (Zone 2, i=1, j=1, k=65) into the file "corner_tip_trail_blade_001.dat" in the residual output folder.

The command (all immediate FSISurfaceInterpolationPressure TURBINE NearestNeighbour) specifies the interpolation method to map the pressure from the fluid mesh surface onto the structure mesh surface. The option "NearestNeighbour" just searches for a structural face the nearest fluid mesh face. Alternatively the option "RadialBasisFunctionC2 <radius>" will trigger the use of radial basis functions with a C2 basis function. However if the number of surface points of the fluid-structure interface is very high the resulting matrix becomes too large and cannot be solved efficiently with the implemented methods. The third method is a conservative interpolation (all immediate FSISurfaceInterpolationPressure TURBINE Conservative) which interpolates the pressure in a conservative way. However this method is only first order conservative and may result in large oscillations of the interpolated pressure on the structure side depending on the surface meshes.

To write the cfd and structural mesh surfaces into a file the command (all immediate FSISurfaceTecplotOutput TURBINE 16 ../output/fsisurface) can be used. The mesh surfaces are written for each 16th timestep of a period (interleave 16 in this example) into the specified path. The data is overwritten after one period. The period is specified in the TRACE unsteady settings with GMC. In this output the structural surface is already transformed onto the cfd mesh and thus it can be used for a quick check to determine the correct transformation of the surface mesh and the interpolation of the surface data. Additionally the flag "subiteration" can be appended to the command. Then every time an FSI coupling iteration is performed the surface data is written.

If the structural model is mirrored or a left hand coordinate system is used the structural model can be mirrored with the command (all immediate FSIMirrorCoordinate TURBINE y). The argument (e.g. "y") determines the axis normal to the mirroring plane.

It is possible to create additional virtual flow passages which are used to map the pressure data onto the structural surface. This is needed if the structural solver can only be used with a full wheel model of the blade row (e.g. with modal dynamics) but only 5 passages of the flowfield are simulated with TRACE. This implies that only a limited amount of nodal diameters (wavenumbers, inter blade phase angles) can be resolved in a simulation. In this case the surface of the cfd mesh is copied and rotated around the x axis (which is assumed to be the symmetry axis of the TRACE setup). Thus the pressure mapped onto the structural surface will repeat itself depending on how many passages are simulated in TRACE. If a blade row has 50 blades (i.e. the structural model has 50 blades) and the TRACE setup consists of 5 blades with periodic boundaries a full wheel cfd surface can be virtually assembled with (all immediate FSICyclicSymmetricVirtualPassages TURBINE 10 10). The first argument specifies the total number of the existing TRACE segments which would be required to build a full blade row (including the existing one). In this example 50/5=10. The second argument specifies the number of segments the user wishes to assemble for the cfd surface. In this example (10 10) a full blade row is assembled and the pressure pattern on the structural surface will repeat itself after every 5 blades.(all immediate FSICyclicSymmetricVirtualPassages TURBINE 10 2) would only add one additional segment to the one modeled in TRACE. This might be useful if CalculiX is not in modal dynamic mode but in full FEM mode with 10 blades modeled and periodic boundaries. By default TRACE will copy and rotate the virtual segments in the mathematical positive sense (right hand rule). In the case of 5 passages in TRACE and the arguments "10 2" one additional segment of the TRACE surface is copied and rotated by 36 degree around the x axis. The direction of rotation can be inverted by appending the flag "clockwise" to the command.

The following three commands are explained above in section Performing Pre-calculations.

The last command FSIExternalSolverActivateNonlinearGeometricEffects will prompt CalculiX to take the geometric variation of surface into account for computing the modal force (if *MODAL DYNAMICS is used). It is necessary to produce consistent results with other linear or nonlinear flutter analysis tools. In case of a full FEM model dynamic analysis (*DYNAMIC) this is not necessary.

Other useful commands are:

(all immediate FSIuseInitialSolutionPressureAsPressureOffset <StructuralSolverInstanceName>) : This will save the initial (mean/static) pressure and use it as an offset. The pressure on the blade surface passed to CalculiX is then subtracted by the offset. This is another possibility to eliminate the static deformations of the structure due to the mean pressure. However the effects of the mean pressure on the structural dynamics are then not accounted for.

The command (all immediate FSIExternalSolverOutputInterleave <StructuralSolverInstanceName> <interleave>) lets CalculiX write output data only each <interleave> timesteps. (If data output is activated in the CalculiX setup.)

With the command (all immediate FSIExternalSolverUseTimeIncrement <StructuralSolverInstanceName>) the time increment setting of the CalculiX setup is used for the structural solver and is not overwritten by TRACE. This enables CalculiX to compute several time increments within one TRACE time step. By default the CalculiX time increment is set equal to the time step size of TRACE.

Simulation

To start a coupled simulation the parameter "-fsi" has to be passed to TRACE, e.g.:

TRACE -cgns TRACE.cgns -cntl TRACE_control.input -fsi

Postprocessing

TRACE will write the aerodynamic work performed at the fluid-structure interface if the residual output is activated in gmc in "fsi_interface_analysis.dat" (in the residual folder).

The mesh deformation of a coupled simulation can be visualized with POST as follows:

POST -i TRACE.cgns -amd -fsi -amp 10.0 -o TRACE.plt

With the argument -amp a factor to magnify the deformation can be specified. The default value is 1.0 (original, physical deformation).

Conjugated Heat Transfer Setup

In the following some examples for a steady conjugated heat transfer (CHT) analysis with TRACE and CalculiX are given.

CalculiX Setup

Following the model definition section in the CalculiX input file (e.g. ccx.inp) CalculiX is set into steady heat transfer analysis mode:

*STEP
*HEAT TRANSFER, STEADY STATE
1,1
*DFLUX
*INCLUDE, INPUT=dfluxsurface.dfl
*END STEP

The file "dfluxsurface.dfl" must contain the surface with heat flux data (in this case 0.0) which is part of the fluid-structure interface. For example:

10, S5, 0.0
20, S5, 0.0
30, S5, 0.0
40, S5, 0.0
50, S5, 0.0
60, S5, 0.0
70, S5, 0.0
80, S5, 0.0
90, S5, 0.0
...

The magnitude of the heat flux (in the example above 0.0) does not matter (for a steady FSI simulation) because in the very first coupling iteration TRACE will begin with the simulation and pass the heat flux at the wall to the structural solver.

TRACE Setup

The solid wall surface of the TRACE setup (e.g. the panel family "Wall") which belongs to the fluid-structure interface must be set to isothermal boundary condition with GMC (GMC: PRE-> "Wall" in the tree view -> Heat transfer -> select Temperature). A constant temperature or a temperature distribution from a tecplot ascii file can be selected which is used as numerical initialization of the fluid-structure interface for the CHT analysis.

The TRACE control file could be as follows:

all immediate FSI FLATPLATE ccx Wall
all immediate FSIrelaxation FLATPLATE Aitken
all immediate FSInPseudoTimeStepsCoupling 500
all immediate FSIUnitConversionHeat FLATPLATE 1.0e-6 1.0
all immediate FSITransformationMatrix FLATPLATE transformation.dat
all immediate FSISurfaceInterpolationPressure FLATPLATE NearestNeighbour

The first command all immediate FSI FLATPLATE ccx Wall) creates a CalculiX instance with the name "FLATPLATE". This is the first command which must specified since most of the following FSI commands will relate to a CalculiX instance (in this case the instance "FLATPLATE"). Note that currently only a single CalculiX instance is supported. The first argument after the CalculiX instance is the name of the CalculiX input file but without the file extention (ccx.inp -> ccx). Then all TRACE panel families follow which are part of the fluid-structure interface on the fluid side (usually the blade surface).

The second command (all immediate FSIrelaxation TURBINE Aitken) specifies the FSI coupling algorithm (currently "FixedPoint" or "Aitken" are available). FixedPoint means that in each iteration the updated displacement data coming from CalculiX is passed to TRACE with a relaxation factor (e.g. all immediate FSIrelaxation FLATPLATE FixedPoint 0.8). If the relaxation factor is set to 1.0 there is no relaxation. Alternatively the Aitken method can be used as in this example.

The next command (all immediate FSInPseudoTimeStepsCoupling 500) specifies the number of iterations (steady solver) or pseudo-time steps (unsteady solver) TRACE is performing between two consecutive FSI coupling iterations. In this example the first coupling iteration occurs at iteration 500 and the second one at iteration 1000 and so on. For more details on the unsteady case see TRACE Setup.

With (all immediate FSIUnitConversionHeat FLATPLATE 1.0e-6 1.0) the unit conversion factors are specified. TRACE always uses SI units. In this example CalculiX expects the heat flux in W/mm^2 (W/m^2 to W/mm^2: 1.0e-6) and returns the temperature in K (K to K: 1.0).

To map the structural mesh onto the cfd mesh the transformation matrix is specified via (all immediate FSITransformationMatrix FLATPLATE transformation.dat). The transformation matrix can be determined with GMC (MTU only), PREP or manually. If no transformation matrix is specified TRACE will try to fit the two meshes onto each other by calculating the area moment of inertia and writes the transformation matrix in the file "transformation_written.dat".

The command (all immediate FSISurfaceInterpolationPressure FLATPLATE NearestNeighbour) specifies the interpolation method to map the heat flux from the fluid mesh surface onto the structure mesh surface. The option "NearestNeighbour" just searches for a structural face the nearest fluid mesh face. Alternatively the option "RadialBasisFunctionC2 <radius>" will trigger the use of radial basis functions with a C2 basis function. However, if the number of surface points of the fluid-structure interface is very high the resulting matrix becomes too large and cannot be solved efficiently with the implemented methods. The third method is a conservative interpolation (all immediate FSISurfaceInterpolationPressure FLATPLATE Conservative) which interpolates the heat flux in a conservative way. However, this method is only first order conservative and may result in large oscillations of the interpolated heat flux on the structure side depending on the surface meshes.

Simulation

To start a coupled simulation the parameter "-fsi" has to be passed to TRACE, e.g.:

TRACE -cgns TRACE.cgns -cntl TRACE_control.input -fsi

FSI SImulation with PyTRACE

TRACE can be coupled to external solvers using pyTRACE. With pyTRACE it is possible to control steady and unsteady simulations and interrupt the solver iterations/time stepping for coupling. In order to exchange data (e.g. temperature, heat flux, pressure or displacements) either the interface offered by pyTRACE or the FSDM Trace Interface (FSTraceInterface) can be used. FSTraceInterface has the advantage that it is part of the FSDM library, which offers routines for surface data interpolation, mesh deformation and more. In order to use these interfaces, TRACE must be compiled with Python extensions. For a conjugate heat transfer simulation there is no special treatment necessary. For aeroelastic simulations with deforming surfaces, TRACE must be started with the '-fsi' flag followed by an option describing the configuration the displacements refer to (reference or current) together with the type of displacements which are supplied to TRACE (surface or whole mesh). In the case of surface displacements, the TRACE internal mesh deformation module is activated. Currently only the mode 'AbsoluteSurfaceDeformationViaPython' is supported, e.g.:

cmd_line = "-cgns TRACE.cantilever.cgns -fsi AbsoluteSurfaceDeformationViaPython Cantilever"
trace = TRACE(cmd_line)

The keyword after 'AbsoluteSurfaceDeformationViaPython' specifies the TRACE panel group which serves as fluid-structure interface. On this surface, the displacements are considered for the mesh deformation. For further information on coupling via pyTRACE/FSTraceInterface please consult the pyTRACE documentation and the FSTraceInterface examples.